Common Specification
TARE | Zero to Full weighing range |
---|---|
SPAN ADJUSTMENT | LF-R・・・・・ Automatic and semi-automatic Span Adjustment with built-in calibration weight LF・・・・・Manual opration Span Adjustment with external calibration weight |
OVER ERROR | “o-Err” showed when Full weight range + 9 more digits over |
TEMPERATURE AND HUMIDITY RANGE | 10~ 30℃、Up to 80% rh(without the dew condensation) |
POWER SOURCE | AC adapter Input 100-240VAC / Output 5.95VDC |
OUTPUT | RS232C output (D-sub 9pin) USB output |
Features
- Automatic Span Adjustment Function to keep maintain high accuracy.
Advice CAL function to notify proper calibaration timing. - Combination Door which opens to left/right/double door
- Windshield designed for wide and space saving
- Large and eye-friendly display unit with back-light
- Able to use as Counting Scale
- Standard equipped USB Output
Outclassing usage of Windshield unit.
In keeping wider space of scale capacity, wind shield is a two step slide door type, so that no flared section comes out from backside. It is a space saving design. Because it is a combination door, it can open to left/right/double side and close by one hand. Able to achieve operational efficiency with using both hands.
Full Automatic Span Adjustment function to keep high-accuracy.
Full-automatic Span Adjustment function,which automatically detect a shift in the environment like ambient temparature change or lomger time usagea and calibrate (span adjustment) scale, is equipped. Periodic calibration maintains high-accuracy of the scale. In addition, Advice CAL function to inform the timing of calibration makes calibration easier.
Variety weighing mode
Weighing mode setting for gravity, percent, counting and jewellery scale. Reliable scale with variety weighing modes in small body enclosure.
Bar graph display to indicate available weighing range.
Usage status to scale capacity is displayed in 40 fraction bar graph. Able to grasp the remaining weighing range at grance.
Large display unit with back-light.
Large and eye-friendly LCD display with 16.5 mm character hight can still read off in the dark workplace.
Standard equipped RS-232C and USB
Bidirectional RS-232C output and USB are standard equipped. Able to communicate with peripheral equipment, like printer etc, or PC.
Print date and time with ISO/GLP/GMP compliant format.
Able to print calibration records in ISO/GLP/GMP compliant format with date and time stamp when Shinko printer is connected.
Specification
Model name | LF225DR | LF224R | |||
Capacity | 92g | 220g | 220g | ||
Readability (d) | 0.01mg | 0.01mg | 0.1mg | ||
Verification intervals (e) | – | – | – | ||
Repeatability | 0.02mg | 0.1mg | 0.1mg | ||
Linearity | ±0.03mg | ±0.2mg | ±0.2mg | ||
Stabilization time | 5.0 sec. | 3.0 sec. | 3.0 sec. | ||
Pan size | 80mm dia | ||||
Dimentions(WDH) | 210×320×335mm(Including Windshield) |
Functions
- Back-light LCD display
- Counting
- Percent
- Carat
- Momme
- Coefficient
- Specific gravity
- Statictic calculation
- Stand-by
- Switching function of Min. readbilitry
- Doublr range
- Comparator (Limit)
- Accumulative adding
- Bar-Graph indication
- Manual oparation calibration delete
- Built-in automatic calibration weight
- RS232C output
- Print output
- ISO/GLP/GMP compliant print
- Clock/Calender
- RTS software download
- Under weight
Option
MODEL NO. | OPTION NAME |
---|---|
LFDK | Density measurement kit |
Peripheral equipment
MODEL NO. | PERIPHERAL NAME |
---|---|
CBM-910Ⅱ | Standard Printer |
CSP-160Ⅱ | Statistics Printer |
LAS-04D-SD | “No wind” Ionizing blower |
RTS | Data-collecting Software |